A module has _______if there is some logical relationship in the elements of a module.
1.Logical cohesion
2.Temporal cohesion
3.Both A And B
4.None of these
In what type of coupling, the complete data structure is passed from one module toanother?
1.Control Coupling
2. Stamp Coupling
3.External Coupling
4.Content Coupling
Unit testing is done by
1.Users
2.Developers
3.Customers
4.None of the mentioned
Which of the following is the worst type of module coupling?
1. Control Coupling
2.Stamp Coupling
3.External Coupling
4.Content Coupling
. In specific design process activites a A.
1.Architectural design.
2.Abstract specification
3.Interface design
4.All of the above
. Which of the following is the worst type of module cohesion?
1. Logical Cohesion
2.Temporal Cohesion
3.Functional Cohesion
4.Coincidental Cohesion
A data dictionary is created when a __________ created.
1. Instance
2.Segment
3.Database
4.Dictionary
A software engineer must design the modules with the goal of high cohesion and lowcoupling.
1.True
2.False
3.all
4.None of These
Acceptance testing is also known a
1.Grey box testing
2.White box testing
3.Alpha Testing
4.Beta testing
Alpha testing is done a
1. A. Developer’s end
2.User’s end
3.Developer’s & User’s end
4.None of the mentioned
Behavioral testing
1. White box testing
2. Black box testing
3.Grey box testing
4.None of the mentioned
Beta testing is done a
1.User’s end
2.Developer’s end
3.User’s & Developer’s end
4.None of the mentioned
Capitalize initial keyword – This is a rule while writing a pseudo code.
1.True
2.False
3.all
4.none
Exhaustive testing
1. A. always possible
2.practically possible
3.impractical but possible
4.impractical and impossible
If all tasks must be executed in the same time-span, what type of cohesion is beingexhibited?
1.Functional Cohesion
2.Temporal Cohesion
3.Functional Cohesion
4.Sequential Cohesion
Keep the statement language ______________ while writing a pseudo code.
1.Dependent B. C. D.
2.Independent
3.Case sensitive
4.Capitalized
Modules with _______ must have good cohesion.
1.Factoring
2. Fan-in
3.Fan-out
4.System shape
Relational schemas and other metadata about relations are stored in a structure called the____________
1.Metadata
2.Catalog
3.Log
4.Data Dictionary
structured design was developed by ----- and --------------------.
1.ED Yourdon and Larry constatine
2. By codd
3. All of these
4.None of these
Testing done without planning and Documentation is ca
1. Unit testing
2.Regression testing
3.Adhoc testing
4.None of the mentioned
The -----------involves the use of parameterized subprograms.
1.Functional Abstraction
2.Control Abstraction
3.Cohesion
4.Cohesion
The testing in which code is check
1. Black box testing
2.White box testing
3.Red box testing
4.Green box testing
The ________ is used to state a desired effect without stating the exact mechanism ofcontrol.
1. Functional Abstraction
2.Control Abstraction
3.Cohesion
4.Coupling
This module gets data from super-ordinates, process that data and again forward It tosuper-ordinate modules, These modules are used for processing purpose.
1.Afferent modules
2.Efferent modules
3.Co-ordinate modules
4.Transform modules.
Which of the following is black box testing
1. Basic path testing
2.Boundary value analysis
3.Code path analysis
4.None of the mentioned
Which of the following is non-functional testing?
1. Black box testing
2.Performance testing
3.Unit testing
4.None of the mentioned
Which of the following is not used in measuring the size of the softwa
1. KLOC
2.Function Points
3.Size of module
4.None of the mentioned
Which of the following is the best type of module coupling?
1.Control Coupling
2.Stamp Coupling
3.Data Coupling
4.Content Coupling
Which of the property of software modularity is incorrect with respect to benefitssoftware modularity?
1. Modules are robust
2.Module can use other modules
3.Modules Can be separately compiled and stored in a library
4.Modules are mostly dependent
White Box techniques are also classified a
1.Design based testing
2.Structural testing
3. Error guessing technique
4.None of the mentioned
__ This module manages the flow of data between different sub-ordinates. They areused for selection purpose and in decision making.
1. Afferent modules
2.Efferent modules
3.Co-ordinate modules
4.Transform modules.
___ it is a module where the number of immediate bosses it has.
1.Factoring
2.Fan-in
3.Fan-out
4.System shape
___ This module gets data from sub-ordinates and forward it tosuperordinate(boss) modules.
1.Afferent modules
2.Efferent modules
3.Co-ordinate modules
4.Transform modules.
____ In this each module hides the representation details of a major data structurebehind functions that access and modify the data structure.
1.Information hiding criteria
2.Conventional criteria
3.Data abstraction criteria
4.None of these
_____ In this each module hides a difficult or changeable design decision from theother module.
1.Information hiding criteria
2.Conventional criteria
3.None of these
4.None of these
_____ This module gets data from super-ordinate and forward it to sub-ordinates.
1.Afferent modules
2.Efferent modules
3.Co-ordinate modules
4.Transform modules.
_______ defined as a collection of program statements with four basic attribute i.e. inputand output, function, mechanics and internal data
1.Module
2.Factoring
3.Fan in
4.Fan Out
_______ is used to show hierarchy in a pseudo code.
1. Indentation
2.Curly Braces
3.Round Brackets
4.Semicolon
________in this each module and its dub module corresponding to a processing step inthe execution sequence.
1.Information hiding criteria
2.Conventional criteria
3.Data abstraction criteria
4.None of These
___________is the separation of a function contained as code in one module into a newmodule of its own.
1.. Factoring
2. Fan-in
3. Fan-out
4.System shape
______________ is a measure of the degree of interdependence between modules.
1.Cohesion
2.Coupling
3.None of the mentioned
4.All of the mentioned